  • To enter programming mode, disconnect the power for 30 seconds. After the initial installation it may be necessary to remove power at the fuse box.

  • Within 2 minutes of re-connecting power to the timer, press the Start button and hold for 10 seconds. The buzzer will sound 2 beeps and the display will flash “P1”.

  • Repeatedly press the button to cycle through the program options in accordance with the table shown below. When the desired shower setting is displayed, press and hold the button for approximately 3 seconds (holding for 10 secs will take you out of programming mode). To confirm your selection, the buzzer will beep when you release the button and the display will cease flashing.

  • If you want to change the shower prevention time between showers, continue pressing the button to advance to the desired prevention time. Press and hold for approximately 3 seconds. (Buzzer will beep when you release the button)

  • When in programming mode, the display will flash on all except the two currently selected options.

  • Holding the button for 10 seconds will return the timer to Normal mode. Failure to press the button during any period of 30 seconds will also return the timer to Normal mode.

In the following table, the left hand column indicates the cycling sequence and the visual display. The other two columns interpret the display options into Shower time and Shower prevention time:

DISPLAY    

SHOWER    

PREVENTION

 

P1

1 min

 

 

P2

2 mins

 

 

P3

3 mins

 

 

P4

4 mins

 

 

P5

5 mins

 

 

P6

6 mins

 

 

P7

7 mins

 

 

P8

8 mins

 

 

P9

9 mins

 

 

P10

10 mins

 

 

P11

11 mins

 

 

P12

12 mins

 

 

00

No shower

 

 

L0

 

No waiting

 

15

15 seconds

 

30

30 seconds

 

L1

1 minute

 

L2

2 minutes

NOTE: In a domestic situation the owner can choose to have the power supply manually switched on and off from within the bathroom. It could be associated with the exhaust fan (piggy back) and switched on and off with the fan.

In this case, the timer operates normally while the power is on but turning the switch off and on again resets the timer to Normal mode – ready to go again immediately.

 

 

Shower Timer product | Shower Timer support | Shower Timer the company Water Saving, Electricity Saving and Gas Saving Tips

 
The Product
Purchase
Support
  - Installation
  - Programming
  - Questions
  - Savings
    Calculator
Industry Links
  - Water Saving
  - Electricity
    Saving
  - Gas Saving
About Us
Link to Us
Contact Us
     
Shower Timer Home